All public logs
Combined display of all available logs of ASDSO Dam Safety Toolbox. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD3.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD2.jpg
- 21:59, 21 June 2022 Camrenbt talk contribs uploaded File:JointD1.jpg
- 21:54, 21 June 2022 Camrenbt talk contribs created page Joint Deterioration - Pay me now or pay me later (Created page with "<div style= "text-align:center;">''Message: Repair damaged concrete joints quickly.''</div> ----</br> Deterioration of concrete joints can repaired cost effectively – but it must be caught early. Once joint sealing compound is gone and gaskets start to appear, a major repair (sliplining or replacement) is on the horizon. <gallery mode="slideshow"> File:JD1.jpg|Joints were rapidly deteriorating in this eastern Montana dam File:JD2.jpg|Joint sealing compound was missin...")
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC4.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC3.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC2.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:CSC1.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs created page File:Service Life.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs moved page Inspect Full Length Pipe to Inspect Full Length of Pipe
- 21:16, 21 June 2022 Camrenbt talk contribs created page Treatment Types (Created page with "<div style= "text-align:center;">''Message: Proper coatings significantly increase the performance of Corrugated Metal Pipe.''</div> ----</br> {{Picture |image= <!-- Add image file name (ex.image.jpg) --> Service Life.jpg |link= <!--Add link if applicable --> |caption= <!-- Add picture caption --> National Corrugated Steel Pipe Association 2008 }} '''Galvanized Steel Pipe''' Pre-galvanizing is the most widely used and most economical metallic coating for corrugated ste...")
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC4.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC3.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC2.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:CSC1.jpg
- 21:16, 21 June 2022 Camrenbt talk contribs uploaded File:Service Life.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC3.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC2.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page File:BC1.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs created page Bituminous Coating Impact on Design Life of Pipe (Created page with "<div style= "text-align:center;">''Message: Bituminous Coating significantly extends conduit design life.''</div> ----</br> This CMP conduit was recently removed from a Judith Basin County, MT dam. The pipe is still in acceptable structural condition, with no significant corrosion showing on the pipe interior. The bituminous coating was an integral component of the corrosion protection. <gallery mode="slideshow"> File:BC1.jpg|Recently removed bituminous coated CMP File...")
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC3.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC2.jpg
- 21:07, 21 June 2022 Camrenbt talk contribs uploaded File:BC1.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page File:CAR2.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page File:CAR1.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs created page Connection between Riser and Conduit often First to Fail (Created page with "<div style= "text-align:center;">''Message: Corrosion at the connection between a drop inlet and the conduit is the cause of many dam failures.''</div> ----</br> The connection between the drop pipe and the conduit can be difficult to evaluate. However, the condition of the connection is very important and corrosion can be a serious problem. Even if the rest of the pipe appears to be in good condition, the connection may not be. <gallery mode="slideshow"> File:CAR1.jpg...")
- 21:01, 21 June 2022 Camrenbt talk contribs uploaded File:CAR2.jpg
- 21:01, 21 June 2022 Camrenbt talk contribs uploaded File:CAR1.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL6.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL5.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL4.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL3.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL2.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page File:IFL1.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs created page Inspect Full Length Pipe (Created page with "<div style= "text-align:center;">''Message: Careful Inspection is required for CMP, even if the initial impression is good.''</div> ----</br> Upon initial inspection, a conduit may appear to be in decent condition with many years of service remaining. However, a simple observation at each end of a pipe will not provide enough information to determine the condition of a pipe. A camera inspection of the full length of a pipe will provide more detail and can often be done...")
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL6.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL5.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL4.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL3.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL2.jpg
- 20:56, 21 June 2022 Camrenbt talk contribs uploaded File:IFL1.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF3.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF2.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page File:COF1.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs created page Corrosion Occurs from Outside In (Created page with "<div style= "text-align:center;">''Message: Corrosion often begins outside and moves inside.''</div> ----</br> The soil surrounding a conduit can be more corrosive than the water inside the pipe. When this occurs, the pipe will corrode faster on the outside than the inside. By inspecting the inside of the pipe, it may appear to be in good condition, however, the pipe may be brittle due to corrosion on the outside. <gallery mode="slideshow"> File:COF1.jpg|This picture s...")
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF3.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF2.jpg
- 20:43, 21 June 2022 Camrenbt talk contribs uploaded File:COF1.jpg
- 15:44, 21 June 2022 Camrenbt talk contribs created page File:DaI3.jpg
- 15:44, 21 June 2022 Camrenbt talk contribs created page File:DaI2.png
