| [[Image:outlet1.jpg|350px|x350px|link=Outlet Configuration]] | |||
|- | |||
|style="text-align:center; font-size:90%;"| Learn more about [[Outlet Configuration|typical configurations of outlet works]] (Photo Source: [https://damoutletworks.org/Pages/GatesValves/GatesValves1.html DamOutletWorks.org]). | |||
|} | |||
<!-- Delete any sections that are not necessary to your topic. Add pictures/sections as needed --> | <!-- Delete any sections that are not necessary to your topic. Add pictures/sections as needed --> | ||
“An outlet works is a combination of structures and equipment required for the safe operation and control of water released from a reservoir to serve various purposes (i.e., regulating stream flow and quality; releasing floodwater, providing irrigation, municipal, and/or industrial water)”.<ref name="FEMA Outlet Works">[[Technical Manual: Outlet Works Energy Dissipators (FEMA P-679) | Technical Manual: Outlet Works Energy Dissipators, FEMA, 2010]]</ref> | “An outlet works is a combination of structures and equipment required for the safe [[operation]] and control of water released from a reservoir to serve various purposes (i.e., regulating stream flow and quality; releasing floodwater, providing [[irrigation]], municipal, and/or industrial water)”.<ref name="FEMA Outlet Works">[[Technical Manual: Outlet Works Energy Dissipators (FEMA P-679) | Technical Manual: Outlet Works Energy Dissipators, FEMA, 2010]]</ref> <u>Note that although outlet works are often necessary for the proper operation of a dam/reservoir system, they can create a distinct vulnerability in the system. Most outlet works include a conduit penetration and discontinuity within the dam or abutment/foundation, and therefore require careful and judicious design, inspection, and maintenance.</u> | ||
The outlet works is an essential component of any dam where the structure does not allow a continuous flow of water over the face of the dam. The discharge capacity and required outflows from the dam via the outlet works are determined by several factors including the purpose of the dam and/or federal and state regulation(s). | The outlet works is an essential component of any dam where the structure does not allow a continuous flow of water over the face of the dam. The discharge capacity and required outflows from the dam via the outlet works are determined by several factors including the purpose of the dam and/or federal and state regulation(s). | ||
“Outlet works serve to regulate or release water impounded by a dam. It may release incoming flows at a reduced rate, as in the case of a detention dam; deliver inflows into canals or pipelines, as in the case of a diversion dam; or release stored-water at such rates as may be dictated by downstream needs, evacuation considerations, or a combination of multiple-purpose requirements”.<ref name="USACE Hydrologic Requirements">[[Hydrologic Engineering Requirements for Reservoirs (EM 1110-2-1420) |EM 1110-2-1420 Hydrologic Engineering Requirements for Reservoirs, USACE, 1997]]</ref> | “Outlet works serve to regulate or release water impounded by a dam. It may release incoming flows at a reduced rate, as in the case of a detention dam; deliver inflows into [[canals]] or pipelines, as in the case of a diversion dam; or release stored-water at such rates as may be dictated by downstream needs, evacuation considerations, or a combination of multiple-purpose requirements”.<ref name="USACE Hydrologic Requirements">[[Hydrologic Engineering Requirements for Reservoirs (EM 1110-2-1420) |EM 1110-2-1420 Hydrologic Engineering Requirements for Reservoirs, USACE, 1997]]</ref> | ||
“Outlet structures can be classified according to their purpose, their physical and [[structural]] arrangement, or their hydraulic operation… Low level outlets are provided to maintain downstream flows for all levels of the reservoir operational pool. The outlets may also serve to empty the reservoir to permit inspection, to make needed repairs, or to maintain the upstream face of the dam or other structures normally inundated… Outlet works may act as a flood-control [[regulator]] to release water temporarily stored in flood control storage space or to evacuate storage in anticipation of flood inflows. In this case, the outflow capacity should be able to release channel capacity, or higher. The flood control storage must be evacuated as rapidly as safely possible, in order to maintain flood reduction capacity”.<ref name="USACE Hydrologic Requirements" /> | |||
==Components of Outlet Works== | ==Components of Outlet Works== | ||
“The outlet works typically | “The components of outlet works, starting from the upstream end, typically consist of an approach channel, an intake structure, a conduit or a tunnel, a control gate chamber, (located in the intake structure, within the conduit, or at the downstream end of the conduit), an exit chute, an energy dissipater, and a discharge channel. Outlet works are frequently used to pass diversion flows during [[construction]], regulate flood flows, aid in emptying the reservoir in an emergency condition, and permit reservoir lowering for [[inspections]] and special repairs”.<ref name="USACE Structural Design Outlet Works">[[Structural Design and Evaluation of Outlet Works (EM 1110-2-2400) | EM 1110-2-2400 Structural Design and Evaluation of Outlet Works, USACE, 2003]]</ref> | ||
The selection of the size, type, and location of the outlet works varies from one dam to the next and is highly dependent on the type of dam and the intended project purpose(s), the required discharge capacity, the specific hydrologic conditions, or [[Hazard Potential Classification|hazard potential classification]]. When designing the layout and control mechanism of the conduit or tunnel used in the outlet works, two classifications are often used, each with their own advantages and disadvantages: [[Downstream Control|downstream control]] and [[Upstream Control|upstream control]]. | |||
“The | “The location of the control features within the outlet works affects the risk associated with internal erosion and backward erosion piping incidents. [[Downstream Control|Downstream control]] features can allow pressurized conditions to occur in the upstream portion of the conduit. Pressurized conditions create a greater potential for water escaping under pressure, potentially eroding the surrounding earthfill or foundation [[soils]]. Careful consideration is required in selecting the location of control features”.<ref name="FEMA Conduits through Embankments">[[Technical Manual: Conduits through Embankment Dams (FEMA P-484) | FEMA 484 Technical Manual: Conduits through Embankment Dams, FEMA, 2005]]</ref> [[Downstream Control|Downstream control]] allows for easier access to any valves or gates used to control the outlet works, as they can be contained within a galley inside the dam or in an appurtenant structure at the toe of the dam. This simplifies any work associated with inspecting, servicing, or replacing the gates or valves. Industry practice for outlet works with downstream controls is to provide provisions for upstream closure in case of an emergency. | ||
[[Upstream Control|Upstream control]] of the outlet works avoids the constant pressurization of the conduit or tunnel, and the risks associated with it, but has its own disadvantages. Upstream gates or valves are located underwater, meaning that they are more difficult to inspect, service, or replace. | |||
==Life Cycle of Outlet Works== | ==Life Cycle of Outlet Works== | ||
Line 28: | Line 32: | ||
==Examples== | ==Examples== | ||
{{Website Icon}} | {{Website Icon}} [[Outlet Configuration|Learn more about outlet configuration]] | ||
==Best Practices Resources== | {{Website Icon}} [[Filters and Drains|Learn more about filters and drains for outlet works]] | ||
{{Document Icon}}[[Technical Manual: Outlet Works Energy Dissipators (FEMA P-679)]] | {{Website Icon}} [[Accounting for Energy Dissipation|Learn more about accounting for energy dissipation at outlet works]] | ||
{{Document Icon}}[[ | {{Website Icon}} [https://damfailures.org/lessons-learned/all-dams-need-an-operable-reservoir-drain-system/ Learn about the importance of having an operable reservoir drain system (DamFailures.org)] | ||
{{Document Icon}}[[ | |||
{{Document Icon}}[[ | <noautolinks>==Best Practices Resources==</noautolinks> | ||
{{Document Icon}}[[Technical Manual: Outlet Works Energy Dissipators (FEMA P-679) | Technical Manual: Outlet Works Energy Dissipators (FEMA P-679), FEMA]] | |||
{{Document Icon}}[[Technical Manual: Conduits through Embankment Dams (FEMA P-484) | Technical Manual: Conduits through Embankment Dams (FEMA P-484), FEMA]] | |||
{{Document Icon}}[[Hydrologic Engineering Requirements for Reservoirs (EM 1110-2-1420) | Hydrologic Engineering Requirements for Reservoirs (EM 1110-2-1420), USACE]] | |||
{{Document Icon}}[[Design Standards No. 14: Appurtenant Structures for Dams (Ch. 1: Introduction) | Design Standards No. 14: Appurtenant Structures for Dams (Ch. 1: Introduction), USBR]] | |||
==Trainings== | ==Trainings== | ||
{{Video Icon}} | {{Video Icon}} [https://youtu.be/TuQUf-nieVY ASDSO Dam Owner Academy: Spillways & Outlet Works] | ||
<!-- For information on notation for in text citations visit https://www.mediawiki.org/wiki/Help:Cite Or simply enclose the citation as shown <ref> citation </ref> in the location of the in text mention. Citations will automatically populate below--> | <!-- For information on notation for in text citations visit https://www.mediawiki.org/wiki/Help:Cite Or simply enclose the citation as shown <ref> citation </ref> in the location of the in text mention. Citations will automatically populate below--> |
Latest revision as of 22:42, 28 July 2023
Learn more about typical configurations of outlet works (Photo Source: DamOutletWorks.org). |
“An outlet works is a combination of structures and equipment required for the safe operation and control of water released from a reservoir to serve various purposes (i.e., regulating stream flow and quality; releasing floodwater, providing irrigation, municipal, and/or industrial water)”.[1] Note that although outlet works are often necessary for the proper operation of a dam/reservoir system, they can create a distinct vulnerability in the system. Most outlet works include a conduit penetration and discontinuity within the dam or abutment/foundation, and therefore require careful and judicious design, inspection, and maintenance.
The outlet works is an essential component of any dam where the structure does not allow a continuous flow of water over the face of the dam. The discharge capacity and required outflows from the dam via the outlet works are determined by several factors including the purpose of the dam and/or federal and state regulation(s).
“Outlet works serve to regulate or release water impounded by a dam. It may release incoming flows at a reduced rate, as in the case of a detention dam; deliver inflows into canals or pipelines, as in the case of a diversion dam; or release stored-water at such rates as may be dictated by downstream needs, evacuation considerations, or a combination of multiple-purpose requirements”.[2]
“Outlet structures can be classified according to their purpose, their physical and structural arrangement, or their hydraulic operation… Low level outlets are provided to maintain downstream flows for all levels of the reservoir operational pool. The outlets may also serve to empty the reservoir to permit inspection, to make needed repairs, or to maintain the upstream face of the dam or other structures normally inundated… Outlet works may act as a flood-control regulator to release water temporarily stored in flood control storage space or to evacuate storage in anticipation of flood inflows. In this case, the outflow capacity should be able to release channel capacity, or higher. The flood control storage must be evacuated as rapidly as safely possible, in order to maintain flood reduction capacity”.[2]
Components of Outlet Works
“The components of outlet works, starting from the upstream end, typically consist of an approach channel, an intake structure, a conduit or a tunnel, a control gate chamber, (located in the intake structure, within the conduit, or at the downstream end of the conduit), an exit chute, an energy dissipater, and a discharge channel. Outlet works are frequently used to pass diversion flows during construction, regulate flood flows, aid in emptying the reservoir in an emergency condition, and permit reservoir lowering for inspections and special repairs”.[3]
The selection of the size, type, and location of the outlet works varies from one dam to the next and is highly dependent on the type of dam and the intended project purpose(s), the required discharge capacity, the specific hydrologic conditions, or hazard potential classification. When designing the layout and control mechanism of the conduit or tunnel used in the outlet works, two classifications are often used, each with their own advantages and disadvantages: downstream control and upstream control.
“The location of the control features within the outlet works affects the risk associated with internal erosion and backward erosion piping incidents. Downstream control features can allow pressurized conditions to occur in the upstream portion of the conduit. Pressurized conditions create a greater potential for water escaping under pressure, potentially eroding the surrounding earthfill or foundation soils. Careful consideration is required in selecting the location of control features”.[4] Downstream control allows for easier access to any valves or gates used to control the outlet works, as they can be contained within a galley inside the dam or in an appurtenant structure at the toe of the dam. This simplifies any work associated with inspecting, servicing, or replacing the gates or valves. Industry practice for outlet works with downstream controls is to provide provisions for upstream closure in case of an emergency.
Upstream control of the outlet works avoids the constant pressurization of the conduit or tunnel, and the risks associated with it, but has its own disadvantages. Upstream gates or valves are located underwater, meaning that they are more difficult to inspect, service, or replace.
Life Cycle of Outlet Works
Examples
Learn more about outlet configuration
Learn more about filters and drains for outlet works
Learn more about accounting for energy dissipation at outlet works
Learn about the importance of having an operable reservoir drain system (DamFailures.org)
Best Practices Resources
Technical Manual: Outlet Works Energy Dissipators (FEMA P-679), FEMA
Technical Manual: Conduits through Embankment Dams (FEMA P-484), FEMA
Hydrologic Engineering Requirements for Reservoirs (EM 1110-2-1420), USACE
Design Standards No. 14: Appurtenant Structures for Dams (Ch. 1: Introduction), USBR
Trainings
ASDSO Dam Owner Academy: Spillways & Outlet Works
Citations:
- ↑ Technical Manual: Outlet Works Energy Dissipators, FEMA, 2010
- ↑ 2.0 2.1 EM 1110-2-1420 Hydrologic Engineering Requirements for Reservoirs, USACE, 1997
- ↑ EM 1110-2-2400 Structural Design and Evaluation of Outlet Works, USACE, 2003
- ↑ FEMA 484 Technical Manual: Conduits through Embankment Dams, FEMA, 2005